Why can't we have send and receive within an atomic scope


Why can't we have send and receive within an atomic scope?


The atomic scope was designed to handle Atomicity, Consistency,
Isolation, and Durability (ACID) compliant operations that must either all succeed or
all fail as a group.

This is a classic database transaction style. It is designed to carry
an orchestration from one stable state to another. This is why you cannot both
send and receive from an atomic scope, because by design the message box is not
a lockable resource
.


To accomplish this atomicity, the orchestration engine persists
the entire orchestration state to the message box before the atomic scope begins; it
subsequently persists the orchestration again when the atomic scope completes.

Comments

Post a Comment

Popular posts from this blog

WCF MaxReceivedMessageSize max value in .config

MaxReceivedMessageSize parameter in binding config   file:   For max file size in WCF, we need to set following parameter in binding files. <binding name="MyService"        maxReceivedMessageSize="2147483647"        maxBufferSize="2147483647" transferMode="Streamed" >        <readerQuotas maxDepth="2147483647" maxStringContentLength="2147483647"      maxArrayLength="2147483647" maxBytesPerRead="2147483647" maxNameTableCharCount="2147483647"/> <!-- other binding info here, such as security --> </binding> Max possible size: MaxReceivedMessageSize to 2147483647 (i.e. Int32.MaxValue), which is 2GB For our case, as we are using WsHttpBinding. <wsHttpBinding>         <binding name="wsHttpBindingSettings" maxReceivedMessageSize="2147483647">      ...

Deploying Custom Pipeline Component on BizTalk Server (PROD)

Deploying Custom Pipeline Component on BizTalk Server: ·         Deploying BizTalk Custom Pipeline Component   on BizTalk Server 2006 or Older Version : To deploy the custom Pipeline component on BizTalk server 2006 or older version. We need to add the Custom Pipeline component in GAC as well as “ C:\Program Files (x86)\Microsoft BizTalk Server 2006\Pipeline Components ” folder.   At design time it will access the Pipeline component dll located in “….. Microsoft   BizTalk Server 2006\Pipeline Components ” folder and show the component in pipeline toolbox. At runtime the BizTalk will use the Custom Pipeline component from GAC. ·         Deploying BizTalk Custom Pipeline Component   on BizTalk Server 2006 R2 or New Version : To deploy the custom Pipeline component on BizTalk server 2006 R2 or later version. We need to add the Custom Pipeline component only in “C:\Pr...

biztalk schema remove ns0 prefix

We can remove ns0 prefix simply by set the schema elements property or both elements and attributes properties to be qualified. To do that follow my steps: 1-       Open your schema 2-       Right Click <Schema> and select properties 3-       Use schema property editior and Set [Element FromDefult] to Unqualified , and then set [Attribute FromDefault] to Unqualified if you are using attributes in your schema. After applying the steps above, both XML instances below will be valid: Instance 1 (with ns0) < ns0:Root xmlns:ns0 = " http://RandomBizTalkProject.Schema1 " >   < Field1 > Field1_0 </ Field1 >   < Field2 > Field2_0 </ Field2 > </ ns0:Root > Instance 2 (without ns0) < Root xmlns = " http://RandomBizTalkProject.Schema1 " >   < Field1 > Field1_0 </ Field1 >   < Field2 >...